EMERGENCY PUBLIC ADDRESS SYSTEMS: FIRE ALARM PA SYSTEM REQUIREMENTS + MAINTENANCE

分享这篇文章

2019年4月16日

发生紧急情况时, clear and succinct communication is vital to ensuring people know what to do and where to go. So, what is a public address system (emergency PA system)? 作为更大的 群发通知系统, a public address system can be an effective way of communicating important instructions and create a sense of calm to building occupants. While proven extremely effective, public address systems also have strict standards and requirements. Understanding the importance of a public address system can save you time, effort and money.

What are fire alarm public address system requirements?

The National Fire Alarm and Signaling Code (NFPA 72) includes strict standards for public addressing systems used in either an in-building 群发通知系统 or wide area 群发通知系统. Some important requirements include:

  • A 风险分析 涉及利益相关者, and an evaluation by the designer to determine applicability and compliance with the Chapter 24 requirements.
  • A document provided by the fire alarm PA system designer attesting that the public address system has been evaluated and meets the requirements determined by Chapter 24 and the 风险分析.
  • Following the identification of potential risks for a facility, the stakeholders develop or update the 应急响应计划 to respond to the incidents raised in 风险分析.

Based on the 风险分析 and 应急响应计划, features needed in the emergency public address system can be identified.

What are design + maintenance requirements for public address systems?

As the technology underpinning fire detection and alarm infrastructure has evolved, 所以要有标准. NFPA 72 Chapter 24 voice evacuation requirements include the monitoring of speaker integrity, 指定警告音, priority messaging hierarchy, 可懂度, default emergency sound levels and a means for deactivating the fire alarm system, 在许多其他方面. In the event of an emergency, 根据NFPA规范, notification and direction must be clearly understood in order to direct people to safety. Each facility will have its own operational needs but these robust requirements ensure the public address system serves as an effective fire emergency notification system.

Understanding requirements for installation and documentation to inspection, testing and maintenance can be challenging for public address systems and larger mass notifications all together. 随着代码的不断变化, it’s important that you’re up to date on the latest safety codes to ensure optimum performance and compliance of the emergency PA systems installed.

Need more clarification on specific codes and requirements for 大规模通知系统? 给彩宝网平台发个便条 info@aprender-a-bailar.com or 彩宝网.